Wholesaler & Distributor
By logging in to the password-protected area of CNBM Germany, you confirm the e-business terms of use and general terms and conditions.
Your login details are protected with our multi-factor authentication. Click here to learn more.
CEI 0-21, G98/G99, VDE4105/0124, NC RfG, TR3.2.1, NRS097-2-1, IEC/EN62109- 1/-2, IEC/EN 61000-6-1, IEC/EN 61000-6-3.


| Model | ME-HT10H | ME-HT12H | ME-HT15H |
| Input (PV) | |||
| Max. PV Power (kW) | 15 | 18 | 22.5 |
| Max. PV voltage (V) | 1000 | ||
| MPPT voltage range(V) | 180~850 | ||
| Max. input current of single MPPT(A) | 13 | ||
| Number of MPPT Trackers | 2 | ||
| Strings Per MPPT Tracker | 1 | 2 | |
| Max. short current (A) | 16 | 25 | |
| Start operating voltage (V) | 180 | ||
| Input (BAT) | |||
| Compatible battery type | Lithium-iron/Lead-acid | ||
| Battery voltage range (V) | 125~600 | ||
| Max. charge current (A) | 50 | ||
| Max. discharge current (A) | 50 | ||
| Max. charge/discharge power (W) | 11000/11000 | 13200/13200 | 16500/16500 |
| Max. charging voltage(V) | 600 | ||
| Output (Grid) | |||
| Rated output power(VA) | 10000 | 12000 | 15000 |
| Max. AC output apparent power (VA) | 1100 | 13200 | 16500 |
| Max. AC output current (A) | 15.9 | 19.1 | 23.8 |
| Rated AC voltage (V) | 400 | ||
| AC voltage range (V) | 360~440 | ||
| Rated grid frequency (Hz) | 50/60 | ||
| AC output topology | 3W+N+PE | ||
| Power factor | 0.8 lagging-0.8 leading | ||
| THDI | <3% | ||
| Output (Back up) | |||
| Nominal output voltage (V) | 400 | ||
| Nominal output frequency (Hz) | 50/60 | ||
| Nominal output power (VA) | 10000 | 12000 | 15000 |
| Nominal output current (A) | 14.4 | 17.3 | 21.7 |
| Transfer time (ms) | 10(typ) / 20(max) | ||
| THDu | <2% | ||
| Efficiency | |||
| Battery charge /discharge efficiency | 97.5% | 97.6% | 97.8% |
| DC Max. efficiency | 98.2% | 98.2% | 98.5% |
| Europe efficiency | 97.5% | 97.5% | 97.6% |
| MPPT efficiency | 99.9% | ||
| General data | |||
| Max. operation altitude (m) | 2000 (derating above2000m) | ||
| Noise emission (dB) | <35 | ||
| Ingress protection degree | IP65 | ||
| Operating temperature range (。C) | -25~60 | ||
| Relative humidity (%) | 0~95 (non-condensing) | ||
| Cooling | Natural | ||
| Dimensions (W*H*D) (mm) | 530*600*200 | ||
| Weight (kg) | 31 | 33 | 34 |
| Isolation transformer | No | ||
| Self-consumption (W) | <15 | ||
| Protection | |||
| DC switch | Support | ||
| DC reverse polarityprotection | Support | ||
| Over temperature protection | Support | ||
| Overpower protection | Support | ||
| AC overcurrent protection | Support | ||
| AC short circuit protection | Support | ||
| Insulation detection | Support | ||
| Grid phase protection | Support | ||
| Display and communication | |||
| Display | LED+APP | ||
| Communication interface | RS485, CAN, DRM/RS485 (for Meter), WiFi | ||
| Certifcation | |||
| Grid | CEI 0-21, G98/G99, VDE4105/0124, NC RfG, TR3.2.1, NRS097-2-1 | ||
| Safety | IEC/EN62109- 1/-2 | ||
| EMC | IEC/EN 61000-6-1, IEC/EN 61000-6-3 | ||


ready jump to page, please wait
sure to delete this product?